<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>Teledyne Hastings Instruments Blog</title>
    <link>https://info.teledyne-hi.com/blog</link>
    <description>Teledyne Hastings Instruments mass flow and vacuum instrumentation blog</description>
    <language>en-us</language>
    <pubDate>Wed, 24 Jun 2026 14:42:43 GMT</pubDate>
    <dc:date>2026-06-24T14:42:43Z</dc:date>
    <dc:language>en-us</dc:language>
    <item>
      <title>DV-6S: The Ideal Vacuum Sensor for Truck, Rail and ISO Container Cryogenic Applications</title>
      <link>https://info.teledyne-hi.com/blog/dv-6s-the-ideal-vacuum-sensor-for-truck-rail-and-iso-container-cryogenic-applications</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/dv-6s-the-ideal-vacuum-sensor-for-truck-rail-and-iso-container-cryogenic-applications" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/DV-6S.png" alt="DV-6S" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 14px; line-height: 1.5;"&gt;In cryogenic applications, especially those mounted on trucks, railcars, and ISO containers, vessels face some of the harshest mechanical and environmental conditions in industry. Because these tanks are in motion, often over uneven terrain or long rail routes, the vacuum sensor must be reliable and remain accurate despite constant vibration. Vibration, shock, temperature swings, and outdoor exposure all place immense demands on sensors tasked with delivering reliable vacuum measurements.&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.5;"&gt;&lt;span&gt;Teledyne Hastings Instruments’ DV-6S Thermocouple Gauge Tube was purpose-built to thrive in these environments. Below is a deep dive into what makes the DV-6S uniquely suited for mobile cryogenic vessels.&lt;/span&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;p style="font-size: 14px; line-height: 1.5;"&gt;I&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/DV-6S.png?width=180&amp;amp;height=152&amp;amp;name=DV-6S.png" width="180" height="152" alt="DV-6S" style="height: auto; max-width: 100%; width: 180px; float: right; margin-left: 10px; margin-right: 0px;"&gt;n cryogenic applications, especially those mounted on trucks, railcars, and ISO containers, vessels face some of the harshest mechanical and environmental conditions in industry. Because these tanks are in motion, often over uneven terrain or long rail routes, the vacuum sensor must be reliable and remain accurate despite constant vibration. Vibration, shock, temperature swings, and outdoor exposure all place immense demands on sensors tasked with delivering reliable vacuum measurements.&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.5;"&gt;&lt;span&gt;Teledyne Hastings Instruments’ DV-6S Thermocouple Gauge Tube was purpose-built to thrive in these environments. Below is a deep dive into what makes the DV-6S uniquely suited for mobile cryogenic vessels.&lt;/span&gt;&lt;/p&gt;  
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Cryogenic%20Collage.png?width=635&amp;amp;height=155&amp;amp;name=Cryogenic%20Collage.png" width="635" height="155" alt="Cryogenic Collage" style="height: auto; max-width: 100%; width: 635px;"&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h3&gt; 
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&amp;nbsp;&lt;/h3&gt; 
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;Engineered for Extreme Ruggedness&lt;/span&gt;&lt;/strong&gt;&lt;/h3&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 34%; margin-left: 10px; margin-right: 0px; float: right;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2; border-width: 0px; border-style: none;"&gt; 
  &lt;tbody&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 100%; padding: 4px; border-color: #FFFFFF;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture2-3.png?width=212&amp;amp;height=160&amp;amp;name=Picture2-3.png" width="212" height="160" alt="Picture2-3" style="height: auto; max-width: 100%; width: 212px;"&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 100%; padding: 4px; text-align: center; border-color: #FFFFFF;"&gt;&lt;span style="font-size: 10px;"&gt;&lt;em&gt;Photo courtesy of NCEE Labs (Nebraska Center for Excellence in Electronics)&lt;/em&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;The DV-6S isn’t just a more durable version of our DV-6R ruggedized vacuum gauge tube. It was specifically designed and tested to extensive MIL-STD levels to withstand severe shock and vibration consistent with road vibration, rai&lt;/span&gt;&lt;span style="font-size: 14px;"&gt;l line harmonics, and loading/unloading impacts.&lt;/span&gt;&lt;/p&gt; 
&lt;ul style="list-style-type: disc; line-height: 1.5;"&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Mechanical Shock: MIL-STD 202 Method 213 (&amp;gt;2,000g for 6 ms duration)&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Random Vibration: MIL-STD 202 Method 214 &lt;br&gt;(23.9 grms)&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Sinusoidal Vibration: MIL-STD 202 Method 204 &lt;br&gt;(30g at 3,000 Hz)&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;These specifications exceed what real-world applications encounter, making the DV-6S ideal for equipment subjected to continuous road, rail, or ship movement.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;Corrosion Resistant for Harsh Outdoor Installations&lt;/span&gt;&lt;/strong&gt;&lt;/h3&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;In transport environments, moisture and debris can compromise vacuum sensor performance and reduce lifespan. The DV-6S combats this with:&lt;span style="background-color: yellow;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;ul style="list-style-type: disc; line-height: 1.5;"&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/DV-6S-B-Green-Back.png?width=231&amp;amp;height=167&amp;amp;name=DV-6S-B-Green-Back.png" width="231" height="167" alt="DV-6S-B-Green-Back" style="height: auto; max-width: 100%; width: 231px; float: right; margin: 0px;"&gt;Rugged stainless steel housing built for outdoor environments&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Protective O-ring-sealed aluminum cap to: &lt;/span&gt; 
  &lt;ul style="list-style-type: circle;"&gt; 
   &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Prevent moisture ingress and reduce corrosion of electrical pins&lt;/span&gt;&lt;/li&gt; 
   &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Protect pins and feedthroughs from foreign object damage&lt;/span&gt;&lt;/li&gt; 
  &lt;/ul&gt; &lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Steel lanyard to prevent cap loss during field servicing&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;These design elements support long-term reliability even when the gauge is exposed to weather conditions typical of transportation applications.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&amp;nbsp;&lt;/h3&gt; 
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;Performance and Compatibility&lt;/span&gt;&lt;/strong&gt;&lt;/h3&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;Cryogenic vessels rely on vacuum jacketed insulation to maintain extremely low temperatures. A vacuum sensor like the DV-6S helps operators:&lt;/span&gt;&lt;/p&gt; 
&lt;ul style="list-style-type: disc; line-height: 1.5;"&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Verify integrity of the vacuum jacket&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Detect insulation degradation in early stages&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Ensure safe transport of cryogenic liquids such as LNG, LN&lt;sub&gt;2&lt;/sub&gt;, LOX, LH&lt;sub&gt;2&lt;/sub&gt;, LAr, LCO&lt;sub&gt;2&lt;/sub&gt; and other liquified gases&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;Despite the extremely robust design, the DV-6S maintains the same trusted measurement performance as other DV-6 series vacuum gauge tubes:&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/HPM%20456_nobkgrd.png?width=109&amp;amp;height=183&amp;amp;name=HPM%20456_nobkgrd.png" width="109" height="183" alt="HPM 456_nobkgrd" style="height: auto; max-width: 100%; width: 109px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;ul style="list-style-type: disc; line-height: 1.5;"&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Measurement range: 0.001 to 1 Torr (1 to 1000 mTorr) which is the standard DV-6 Series measurement range&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Fully compatible with Teledyne’s DV-6 Series Instruments like the portable handheld HPM 4/5/6 gauge and others such as the DCVT, DVT, VT-6A, and DAVC.&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;1/8" male NPT connection is standard with options available for KF-25, KF-16, KF-10, and ¼ VCR.&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;This ensures operators can incorporate the DV-6S into existing systems without redesign, making fleet-wide adoption simple and cost effective.&lt;span style="background-color: yellow;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h3 style="line-height: 1.5; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;The Clear Choice&lt;/span&gt;&lt;/strong&gt;&lt;/h3&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/DV-6S-A-Raw.png?width=148&amp;amp;height=119&amp;amp;name=DV-6S-A-Raw.png" width="148" height="119" alt="DV-6S-A-Raw" style="height: auto; max-width: 100%; width: 148px; float: right; margin-left: 10px; margin-right: 0px;"&gt;The Teledyne Hastings Instruments’ DV-6S stands out as a purpose engineered solution for mobile cryogenic vessels. It’s the go-to vacuum sensor for LNG fuel tanks on gas powered trucks. With its extreme shock and vibration performance, rugged outdoor ready design, and precise vacuum measurement capabilities, it delivers reliability in environments where other sensors fail.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;For cryogenic equipment manufacturers and fleet operators alike, the DV-6S offers confidence, safety, and long-term durability – everything needed to keep critical cryogenic systems performing during transport.&lt;/span&gt;&lt;span style="font-size: 14px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/DV-5S_5.png?width=77&amp;amp;height=133&amp;amp;name=DV-5S_5.png" width="77" height="133" alt="DV-5S_5" style="height: auto; max-width: 100%; width: 77px; float: left; margin: 0px 10px 0px 0px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;&lt;/span&gt;&lt;span style="font-size: 14px;"&gt;Note: A DV-5 Series version is also available. The DV-5S offers the same extreme protective features as the DV-6S but covers the DV-5 Range of 0.0001 to 0.1 Torr (0.1 to 100 mT). It’s also compatible with the handheld HPM 4/5/6 vacuum gauge.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 14px;"&gt;Visit &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/dv6-series"&gt;https://www.teledyne-hi.com/en-us/what-we-do/dv6-series&lt;/a&gt; to learn more about the DV-6S vacuum gauge tube.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&lt;span style="font-size: 12px;"&gt;If you have questions about vacuum gauges or vacuum controllers, feel free to contact us by phone (+1-757-723-6531 or 1-800-950-2468), email&lt;a href="mailto:Hastings_Instruments@Teledyne.com"&gt; Hastings_Instruments@Teledyne.com&lt;/a&gt;, or via Live Chat on our website &lt;a href="http://www.teledyne-hi.com"&gt;www.teledyne-hi.com&lt;/a&gt;.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.5;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="line-height: 1.5; font-size: 12px;"&gt;&lt;span style="font-style: italic;"&gt;Vibration test photo provided by NCEE Labs (Nebraska Center for Excellence in Electronics): &lt;a href="https://nceelabs.com/" style="font-style: italic;"&gt;nceelabs.com&lt;/a&gt; : Tel 402-323-6233&lt;/span&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fdv-6s-the-ideal-vacuum-sensor-for-truck-rail-and-iso-container-cryogenic-applications&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>vacuum gauges</category>
      <category>Thermocouple Gauge Tubes</category>
      <category>LNG</category>
      <pubDate>Wed, 24 Jun 2026 14:42:42 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/dv-6s-the-ideal-vacuum-sensor-for-truck-rail-and-iso-container-cryogenic-applications</guid>
      <dc:date>2026-06-24T14:42:42Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>How Teledyne Hastings Mass Flow Meters Ensure Aircraft Safety</title>
      <link>https://info.teledyne-hi.com/blog/aviation-leak-testing</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/aviation-leak-testing" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/AdobeStock_124447892.jpeg" alt="How Teledyne Hastings Mass Flow Meters Ensure Aircraft Safety" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;h1 style="line-height: 1.25; text-align: center; font-weight: bold; font-size: 20px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;How Teledyne Hastings Mass Flow Meters Ensure Aircraft Safety&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;/span&gt;&lt;/h1&gt;</description>
      <content:encoded>&lt;h1 style="line-height: 1.25; text-align: center; font-weight: bold; font-size: 20px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;How Teledyne Hastings Mass Flow Meters Ensure Aircraft Safety&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;/span&gt;&lt;/h1&gt; 
&lt;p style="font-size: 14px; text-align: left; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/AdobeStock_124447892.jpeg?width=366&amp;amp;height=244&amp;amp;name=AdobeStock_124447892.jpeg" width="366" height="244" alt="AdobeStock_124447892" style="height: auto; max-width: 100%; width: 366px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/p&gt;  
&lt;p style="font-size: 14px; text-align: left; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Every day, the skies are busy – approximately 100,000 flights take off and land globally, moving passengers and cargo across continents with remarkable consistency. With this volume of daily air travel, the integrity of every aircraft component is non-negotiable. Even the smallest leak can compromise performance, safety or efficiency.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; text-align: left; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="background-color: transparent;"&gt;This is where Teledyne Hastings Instruments (T&lt;span style="color: #000000;"&gt;HI) plays a pivotal role. &lt;/span&gt;&lt;span&gt;&lt;span style="color: #000000;"&gt;THI offers a range of product families, widely used in aviation leak testing, that h&lt;/span&gt;elp ensure that essential aircraft systems remain tight, reliable and ready for flight by supporting aviation manufacturers and the maintenance, repair and overhaul (MRO) teams as they maintain the highest standards of quality and performance.&lt;/span&gt;&amp;nbsp;&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="background-color: transparent;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="background-color: transparent;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;  
&lt;h2 style="text-align: left; font-weight: bold; line-height: 1.25;"&gt;&lt;span style="background-color: transparent; font-family: Arial, Helvetica, sans-serif; color: #0076c0;"&gt;&lt;br&gt;Why Leak Testing Matters in Aviation&lt;/span&gt;&lt;span style="background-color: transparent; font-family: Arial, Helvetica, sans-serif;"&gt;&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-size: 14px; text-align: left; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="background-color: transparent; font-family: Arial, Helvetica, sans-serif;"&gt;A standard process of the manufacturing and maintenance of nearly every major aircraft system includes leak testing and/or performance testing. Some key aircraft components that are commonly leak-tested include:&lt;/span&gt;&lt;span style="background-color: transparent; font-family: Arial, Helvetica, sans-serif;"&gt; &amp;nbsp;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Applications%20Honeycomb%203.png?width=592&amp;amp;height=403&amp;amp;name=Applications%20Honeycomb%203.png" width="592" height="403" alt="Applications Honeycomb 3" style="height: auto; max-width: 100%; width: 592px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;ul&gt; 
 &lt;li style="line-height: 1.15; font-size: 14px;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;Cabin &amp;amp; Fu&lt;/strong&gt;&lt;strong&gt;selage Pressurization Systems (Cabin Valves)&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Ensure the aircraft can maintain safe cabin pressure throughout all phases of flight.&lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
 &lt;li style="line-height: 1.15; font-size: 14px;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;Fuel Systems&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Detects leakage in lines, valves and components that must remain airtight to prevent safety hazards. &lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
 &lt;li style="font-size: 14px;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;Engine Components&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Verifies integrity of fuel manifolds, nozzles and lines; high-pressure bleed air systems (ducts, couplings); oil system components. &lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
 &lt;li style="font-size: 14px;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;Oxygen Systems &amp;amp; Fire Suppression Lines&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Ensures critical safety systems are fully sealed, reliable and mission-ready &lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
 &lt;li style="font-size: 14px;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;Heat Exchangers&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Verifies performance and integrity of heat exchangers to manage thermal loads in engines, cabin environment control systems (ECS), hydraulic systems and avionics.&lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
&lt;/ul&gt; 
&lt;p&gt;&amp;nbsp;&lt;span&gt;&lt;/span&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="text-align: left; font-weight: bold; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; color: #0076c0;"&gt;Where Teledyne Hastings Fits In&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;For these applications, THI provides their line of thermal mass flow meters. These provide accuracy, speed and repeatability – key advantages for both production environments and high-throughput test standards.&lt;/span&gt;&lt;/p&gt; 
&lt;h3 style="font-size: 16px; font-weight: bold; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Flow Meters Used in Leak Testing&lt;/span&gt;&lt;/h3&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Teledyne Hastings offers three (3) primary product families widely used in aviation leak testing. These flow meters are selected based on the required flow range, speed and sensitivity for the specific test application.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.5;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-weight: bold;"&gt;200 Series&lt;span&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/200Series_nobkgrd.png?width=202&amp;amp;height=123&amp;amp;name=200Series_nobkgrd.png" width="202" height="123" style="height: auto; width: 202px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt; &lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Rugged general-purpose thermal mass flow meters &lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;The 200 Series is known in the industry for its stable output and reliable repeatability. Also, the 200 Series with Laminar Flow Element (HFM-200-LFE) can measure large flow rates with remarkably low pressure drops.&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.5;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-weight: bold;"&gt;300 Series&lt;span&gt;&lt;strong&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/HFM-300_nobkgrd.png?width=126&amp;amp;height=126&amp;amp;name=HFM-300_nobkgrd.png" width="126" height="126" style="height: auto; width: 126px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/strong&gt;&lt;/span&gt; &lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Fast response for dynamic testing&lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;The 300 Series has an extremely fast response time – the sensor has a response time of 300 milliseconds. It also has fold-over protection which prevents large over-ranged leaks from being confused with on-scale values.&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.5;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-weight: bold;"&gt;Digital 300 Series&lt;span&gt;&lt;strong&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/IP-67-HFM-D-301A_nobkgrd.png?width=131&amp;amp;height=131&amp;amp;name=IP-67-HFM-D-301A_nobkgrd.png" width="131" height="131" alt="IP-67-HFM-D-301A_nobkgrd" style="height: auto; width: 131px; float: right; margin-left: 10px; margin-right: 0px; max-width: 100%;"&gt;&lt;/strong&gt;&lt;/span&gt; &lt;/span&gt;&lt;br&gt;&lt;span style="background-color: transparent;"&gt;Fast response with higher accuracy&lt;br&gt;&lt;/span&gt;&lt;span style="background-color: transparent;"&gt;The Digital 300 Series offers the same features as the 300 Series, but it also features improved accuracy and additional features, such as optional local touchscreen display and IP-67 enclosure.&lt;/span&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.25;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; font-weight: normal; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="width: 732px; height: 50px;"&gt;&lt;/span&gt;Each of these product families are available in four (4) Full-Scale (FS) Range sizes, enabling coverage across most aviation leak-test applications and/or performance tests.&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 100%; margin-left: auto; margin-right: auto; font-size: 14px; line-height: 1.25;"&gt; 
 &lt;table style="width: 100%; border: 5px solid #99acc2; height: 39px; background: linear-gradient(to right, #b8e6b8, #fff6b3, #ffd3a6, #ffb3b3); border-width: 1px;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 39px;"&gt; 
    &lt;td style="width: 23.622%; padding: 4px; text-align: center; height: 39px; vertical-align: middle; border-style: hidden; border-color: #000000;"&gt; &lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;span style="font-weight: bold;"&gt;Low Flow&lt;/span&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;0-5 sccm to 0-25 SLM&lt;/span&gt;&lt;/p&gt; &lt;/td&gt; 
    &lt;td style="width: 23.622%; padding: 4px; text-align: center; height: 39px; border-style: hidden; border-color: #000000;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-weight: bold;"&gt;Medium Flow&lt;/span&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 12px;"&gt;0-25 SLM to 0-1,000 SLM&lt;/span&gt;&lt;/p&gt; &lt;/td&gt; 
    &lt;td style="width: 26.4567%; padding: 4px; text-align: center; height: 39px; border-style: hidden; border-color: #000000;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-weight: bold;"&gt;High Flow&lt;/span&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 12px;"&gt;0-1,00&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 12px;"&gt;0 SLM to 0-2,500 SLM&lt;/span&gt;&lt;/p&gt; &lt;/td&gt; 
    &lt;td style="width: 26.2992%; padding: 4px; text-align: center; height: 39px; border-style: hidden; border-color: #000000;"&gt; &lt;p style="line-height: 1;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-weight: bold;"&gt;Ultra-High Flow&lt;/span&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 12px;"&gt;0-2,500 S&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 12px;"&gt;LM to 15,000 SLM&lt;/span&gt;&lt;/p&gt; &lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 14px; line-height: 1.25;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="line-height: 1.25;"&gt;&lt;span style="color: #0076c0;"&gt;What Happens During Aviation Leak Tests?&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Figure%201%20Typical%20Leak%20Check.png?width=230&amp;amp;height=256&amp;amp;name=Figure%201%20Typical%20Leak%20Check.png" width="230" height="256" alt="Figure 1 Typical Leak Check" style="height: auto; max-width: 100%; width: 230px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="line-height: 1.25; text-align: left;"&gt;&lt;span style="font-size: 14px; font-family: Arial, Helvetica, sans-serif;"&gt;A typical leak test is shown in Figure 1. For high throughput leak detection, a pressurized manifold has multiple connections for mass flow meters. On the outlet side of each flow meter is an isolation valve and the test part. When the isolation valve is opened, the test part leaks will be noted by the movement of clean dry air across the flow meter. The test part is only exposed to clean dry air. Leak detection with mass flow meters is faster than alternative methods like pressure decay testing and helium leak detectors. It is also cleaner than hydrotesting, bubble testing and liquid penetrate testing.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="line-height: 1.25; text-align: right;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="line-height: 1.25;"&gt;&lt;span style="color: #0076c0;"&gt;Confidence at 40,000 Feet&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-size: 14px; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;With tens of thousands of aircraft in the air each day, you can fly confidently knowing that Teledyne Hastings Instruments helps keep critical aviation components safe, sealed and flight ready. Our mass flow meters provide the precision, speed and reliability manufacturers and MRO teams depend on.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Beyond performance, Teledyne Hastings products are built for long term stability, making them a trusted choice for high-throughput production environments and demanding aerospace applications. As aircraft systems grow more advanced and global flight activity continues to increase, Teledyne Hastings Instruments remains committed to supporting the aviation industry with measurement solutions engineered for safety, consistency and total peace of mind.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="background-color: #ffffff; font-family: Arial, Helvetica, sans-serif;"&gt;Visit&lt;span style="color: #3574e3;"&gt; &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/thermal-mass-flow" style="color: #3574e3;"&gt;https://www.teledyne-hi.com/en-us/what-we-do/thermal-mass-flow&lt;/a&gt; &lt;/span&gt;to learn more about THI's Mass Flow Meters.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;If you have questions about mass flow meters, feel free to contact us by phone (+1-757-723-6531 or 1-800-950-2468), email &lt;a href="mailto:Hastings_Instruments@Teledyne.com"&gt;Hastings_Instruments@Teledyne.com&lt;/a&gt;, or via Live Chat on our website &lt;a href="http://www.teledyne-hi.com"&gt;www.teledyne-hi.com&lt;/a&gt;.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25;"&gt;&amp;nbsp;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Faviation-leak-testing&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>mass flow meter</category>
      <category>Thermal Mass Flow Meter</category>
      <category>aviation</category>
      <category>leak testing</category>
      <pubDate>Thu, 12 Mar 2026 14:00:00 GMT</pubDate>
      <author>hastings_instruments@teledyne.com (The Teledyne Hastings Team)</author>
      <guid>https://info.teledyne-hi.com/blog/aviation-leak-testing</guid>
      <dc:date>2026-03-12T14:00:00Z</dc:date>
    </item>
    <item>
      <title>Introducing the HVG-PR - The Ideal Vacuum Gauge for OEM Applications</title>
      <link>https://info.teledyne-hi.com/blog/introducing-the-hvg-pr</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/introducing-the-hvg-pr" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/HVG-PR-KF-16_9.png" alt="THI Model HVG-PR" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span&gt;We at Teledyne Hastings Instruments are pleased to introduce the newest member of our vacuum measurement portfolio, the HVG&lt;sub&gt;PR&lt;/sub&gt;. The HVG&lt;sub&gt;PR&lt;/sub&gt; vacuum gauge measures pressures from Atmosphere to 0.1 mTorr (1.3 x 10&lt;sup&gt;-4&lt;/sup&gt; mbar / 1.3 x 10&lt;sup&gt;-2&lt;/sup&gt; Pascal). It uses the same precision pirani sensor found in our proven HVG-2020B wide range gauge. The HVG&lt;sub&gt;PR&lt;/sub&gt; is packaged in a compact and cost-effective design that makes it ideal for OEMs, system integration, and process automation.&lt;/span&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;span&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/HVG-PR-KF-16_9.png?width=215&amp;amp;height=215&amp;amp;name=HVG-PR-KF-16_9.png" width="215" height="215" style="height: auto; width: 215px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span&gt;We at Teledyne Hastings Instruments are pleased to introduce the newest member of our vacuum measurement portfolio, the HVG&lt;sub&gt;PR&lt;/sub&gt;. The HVG&lt;sub&gt;PR&lt;/sub&gt; vacuum gauge measures pressures from Atmosphere to 0.1 mTorr (1.3 x 10&lt;sup&gt;-4&lt;/sup&gt; mbar / 1.3 x 10&lt;sup&gt;-2&lt;/sup&gt; Pascal). It uses the same precision pirani sensor found in our proven HVG-2020B wide range gauge. The HVG&lt;sub&gt;PR&lt;/sub&gt; is packaged in a compact and cost-effective design that makes it ideal for OEMs, system integration, and process automation.&lt;/span&gt;&lt;/p&gt;  
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-size: 16px;"&gt;Accuracy&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;The HVG&lt;sub&gt;PR&lt;/sub&gt; measures from Atmosphere through Medium Vacuum (0.1 mTorr / 1.3 x 10&lt;sup&gt;-4&lt;/sup&gt; mbar / 1.3 x 10&lt;sup&gt;-2&lt;/sup&gt; Pascal). It has great accuracy from 1 mTorr to 100 mTorr while still providing visibility at atmosphere. Most applications use N2 or Air, but the HVG&lt;sub&gt;PR&lt;/sub&gt; has preset gas correction factors to also cover He, Ar, H2, CF4, and SF6.&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 62%; margin-left: auto; margin-right: auto;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2; height: 99.2px;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 24.8px;"&gt; 
    &lt;td style="width: 47.1567%; padding: 4px; background-color: #b6dcf1; height: 24.8px; border-color: #000000;"&gt;&lt;strong&gt;Range&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 53.0128%; padding-top: 4px; padding-right: 4px; padding-bottom: 4px; background-color: #b6dcf1; height: 24.8px; text-align: left; border-color: #000000;"&gt;&lt;strong&gt;Accuracy&lt;/strong&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 24.8px;"&gt; 
    &lt;td style="width: 47.1567%; padding: 4px; height: 24.8px; border-color: #000000;"&gt;100 Torr to 1,000 Torr&lt;/td&gt; 
    &lt;td style="width: 53.0128%; padding: 4px; height: 24.8px; border-color: #000000;"&gt;± 50% of Rdg&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 24.8px;"&gt; 
    &lt;td style="width: 47.1567%; padding: 4px; height: 24.8px; border-color: #000000;"&gt;1 mTorr to 100 Torr&lt;/td&gt; 
    &lt;td style="width: 53.0128%; padding: 4px; height: 24.8px; border-color: #000000;"&gt;± 15% of Rdg&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 24.8px;"&gt; 
    &lt;td style="width: 47.1567%; padding: 4px; height: 24.8px; border-color: #000000;"&gt;0.1 mTorr to 1 mTorr&lt;/td&gt; 
    &lt;td style="width: 53.0128%; padding: 4px; height: 24.8px; border-color: #000000;"&gt;± (50% of Rdg + 0.1 mTorr)&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
 &lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;/div&gt; 
&lt;h2 style="font-size: 16px;"&gt;System Connections&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/system%20connections.png?width=163&amp;amp;height=90&amp;amp;name=system%20connections.png" width="163" height="90" alt="system connections" style="height: auto; max-width: 100%; width: 163px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;The HVG&lt;sub&gt;PR&lt;/sub&gt; is available with two small system connections for system integration: KF-16 flange or 1/8” MNPT. Unlike some pirani vacuum gauges, the HVG&lt;sub&gt;PR&lt;/sub&gt; can be mounted and operate in any orientation: port facing down, port facing up, port facing sideways, port tilted at an angle, etc.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-size: 16px;"&gt;Analog Output and Digital Communication&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;Both models offer two choices of common logarithmic analog output signals for simple integration into OEMs and process automation: 1 V/decade (2-9 VDC) or 1.286 V/decade (1.16-10.1620). The user can easily change from one output to the other. In addition, RS485 digital communication is standard on all units. Power, analog output, and digital communication are provided through a single RJ45 connector.&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 100%; margin-left: auto; margin-right: auto;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2;"&gt; 
  &lt;tbody&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 17.5032%; padding: 4px; background-color: #b6dcf1;"&gt;&lt;strong&gt;Output&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 18.1323%; padding: 4px; background-color: #b6dcf1;"&gt;&lt;strong&gt;@ 0.001 Torr&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 17.9754%; padding: 4px; background-color: #b6dcf1;"&gt;&lt;strong&gt;@ 1,000 Torr&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 23.6518%; padding: 4px; background-color: #b6dcf1;"&gt;&lt;strong&gt;P (Torr) from V (volts)&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 22.8634%; padding: 4px; background-color: #b6dcf1;"&gt;&lt;strong&gt;Volts from P (Torr)&lt;/strong&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 17.5032%; padding: 4px;"&gt;1.00 V/decade&lt;/td&gt; 
    &lt;td style="width: 18.1323%; padding: 4px;"&gt;2.0000 V&lt;/td&gt; 
    &lt;td style="width: 17.9754%; padding: 4px;"&gt;9.000 V&lt;/td&gt; 
    &lt;td style="width: 23.6518%; padding: 4px;"&gt;P=10&lt;sup&gt;(v-6)&lt;/sup&gt;&lt;/td&gt; 
    &lt;td style="width: 22.8634%; padding: 4px;"&gt;V=log&lt;sub&gt;10&lt;/sub&gt;P+6&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 17.5032%; padding: 4px;"&gt;1.286 V/decade&lt;/td&gt; 
    &lt;td style="width: 18.1323%; padding: 4px;"&gt;1.1600 V&lt;/td&gt; 
    &lt;td style="width: 17.9754%; padding: 4px;"&gt;10.1620 V&lt;/td&gt; 
    &lt;td style="width: 23.6518%; padding: 4px;"&gt;P=10&lt;sup&gt;0.778(V-6.304)&lt;/sup&gt;&lt;/td&gt; 
    &lt;td style="width: 22.8634%; padding: 4px;"&gt;V=1.286 log&lt;sub&gt;10&lt;/sub&gt;P+6.304&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-size: 16px;"&gt;Other Features&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;A status LED on the top panel flashes to allow you to approximate your pressure with a quick glance.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;The gauge offers three simple ways to Zero or Span the unit:&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/other%20features.png?width=253&amp;amp;height=118&amp;amp;name=other%20features.png" width="253" height="118" alt="other features" style="height: auto; max-width: 100%; width: 253px; float: right; margin-left: 10px; margin-right: 0px;"&gt; &lt;/span&gt;&lt;/p&gt; 
&lt;ol&gt; 
 &lt;li&gt; &lt;p&gt;&lt;span style="font-size: 12px;"&gt;Recessed Push Button, &lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
 &lt;li&gt; &lt;p&gt;&lt;span style="font-size: 12px;"&gt;Remote Pins 7 &amp;amp; 2&lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
 &lt;li&gt; &lt;p&gt;&lt;span style="font-size: 12px;"&gt;RS485&lt;/span&gt;&lt;/p&gt; &lt;/li&gt; 
&lt;/ol&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-size: 16px;"&gt;Applications&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;The HVGPR is ideal for a wide variety of vacuum applications, but it’s compact size and flexibility make it excellent for OEMs, system integration, and process automation.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;Common &lt;strong&gt;Analytical Instrumentation OEM applications&lt;/strong&gt; include but are not limited to:&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/HVG-PR_Both%20Variants_7_lights.png?width=322&amp;amp;height=322&amp;amp;name=HVG-PR_Both%20Variants_7_lights.png" width="322" height="322" alt="HVG-PR_Both Variants_7_lights" style="height: auto; max-width: 100%; width: 322px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;ul&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Vacuum Centrifuge&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Surface Porosity&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Optical Emission Spectrometers&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;High Pressure Metrology&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;Other common applications include:&lt;/span&gt;&lt;/p&gt; 
&lt;ul&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Semiconductor&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Foreline Monitoring&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Glass Coating&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Thin Film Deposition&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Freeze Drying&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Vacuum Furnace / Heat Treat&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;HVAC / Refrigeration / Ice Machinery&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 12px;"&gt;Oil Reprocessing&lt;span style="background-color: transparent;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="background-color: #ffffff; font-size: 12px;"&gt;Visit &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/hvg-pr"&gt;https://www.teledyne-hi.com/en-us/what-we-do/hvg-pr&lt;/a&gt;&amp;nbsp;to learn more about the HVG&lt;sub&gt;PR&lt;/sub&gt; vacuum gauge.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;If you have questions about vacuum gauges or vacuum controllers, feel free to contact us by phone (+1-757-723-6531 or 1-800-950-2468), email &lt;a href="mailto:Hastings_Instruments@Teledyne.com"&gt;Hastings_Instruments@Teledyne.com&lt;/a&gt;, or via Live Chat on our website &lt;a href="http://www.teledyne-hi.com"&gt;www.teledyne-hi.com&lt;/a&gt;.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fintroducing-the-hvg-pr&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Mon, 02 Feb 2026 16:40:03 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/introducing-the-hvg-pr</guid>
      <dc:date>2026-02-02T16:40:03Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>Service Center Spotlight: Shanghai JeeGa Industrial Co., Ltd</title>
      <link>https://info.teledyne-hi.com/blog/service-center-spotlight-shanghai-jeega-industrial-co.-ltd</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/service-center-spotlight-shanghai-jeega-industrial-co.-ltd" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/Spotlight%20-%20JeeGa.png" alt="InfoRAD Service Center Spotlight Graphic" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;This is the third blog in our series highlighting Teledyne Hastings Instruments’ authorized service partners. These partners are fully authorized to calibrate and repair Teledyne Hastings Instruments’ vacuum gauges, mass flow meters (MFMs), and mass flow controllers (MFCs).&lt;/span&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Spotlight-JeeGa.png?width=635&amp;amp;height=322&amp;amp;name=Spotlight-JeeGa.png" width="635" height="322" alt="Spotlight-JeeGa" style="height: auto; max-width: 100%; width: 635px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;This is the third blog in our series highlighting Teledyne Hastings Instruments’ authorized service partners. These partners are fully authorized to calibrate and repair Teledyne Hastings Instruments’ vacuum gauges, mass flow meters (MFMs), and mass flow controllers (MFCs).&lt;/span&gt;&lt;/p&gt;  
&lt;p style="font-size: 12px; text-align: justify;"&gt;&lt;br&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/JeeGa%20Logo.jpg?width=191&amp;amp;height=70&amp;amp;name=JeeGa%20Logo.jpg" width="191" height="70" alt="JeeGa Logo" style="height: auto; max-width: 100%; width: 191px; float: right; margin: 0px 0px 0px 15px;"&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;This service partner provides calibration and repair service for all of China as well as the Hong Kong and Macau SARs. Lets meet JeeGa!&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture2-1.jpg?width=235&amp;amp;height=161&amp;amp;name=Picture2-1.jpg" width="235" height="161" alt="Picture2-1" style="height: auto; max-width: 100%; width: 235px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;br&gt;Shanghai JeeGa Industrial Co., Ltd. was established in 2014 and is headquartered in one of China's largest cities: Shanghai. In addition, they have a branch office in Wuhan and operate in Hong Kong under the name HK Beimu. JeeGa has been a distributor of Teledyne Hastings Instruments since their start in 2014 and is one of Teledyne's most sophisticated distributors.&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;JeeGa stocks vacuum gauges, vacuum transducers, mass flow meters (MFMs) and mass flow controllers (MFCs) at their Shanghai site. Most common Teledyne Hastings Instrument products are readily available for quick local delivery. The DV-6R and HPM 4/5/6 products are stocked in extremely large quantities. Teledyne HFM-200 (MFMs) and HFC-202 (MFCs) are stocked in kit format. JeeGa can quickly configure, assemble and calibrate HFM-200 MFMs and HFC-202 MFCs to meet your exact gas type, flow rate and pressure requirements to ship these in a short lead time. All units are assembled and calibrated per Teledyne's standards and specifications. JeeGa has literally manufactured thousands of HFM-200s and HFC-202s in their Shanghai facility.&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 75%; margin-left: auto; margin-right: auto;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #000000; height: 133px;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 26px;"&gt; 
    &lt;td style="width: 21.5402%; padding: 4px; background-color: #0076c0; border-color: #000000; height: 26px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #ffffff;"&gt;Category&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 78.4831%; padding: 4px; background-color: #0076c0; border-color: #000000; height: 26px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #ffffff;"&gt;Products Stocked in Korea&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 47px;"&gt; 
    &lt;td style="width: 21.5402%; padding: 4px; border-color: #000000; height: 47px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Flow&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 78.4831%; padding: 4px; border-color: #000000; height: 47px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;HFM-200, HFC-202&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 60px;"&gt; 
    &lt;td style="width: 21.5402%; padding: 4px; border-color: #000000; height: 60px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Vacuum&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 78.4831%; padding: 4px; border-color: #000000; height: 60px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;HPM 4/5/6, DV-6R, DV-6S, DV-6-VCR, DV-6R-CF, DV-5M, DV-5R, DB-20, HVG-2020B&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: center;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture3-2.png?width=1388&amp;amp;height=407&amp;amp;name=Picture3-2.png" width="1388" height="407" alt="Picture3-2" style="height: auto; max-width: 100%; width: 1388px;"&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="font-weight: bold;"&gt;&lt;em&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;HFC-2020 MFC kits assembled and calibrated in Shanghai&lt;/span&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;pre style="line-height: 1.25; text-align: center;"&gt;&amp;nbsp;&lt;/pre&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;JeeGa's calibration and repair lab has been in operation for approximately ten years. New calibration equipment is added each year to continuously grow the lab. JeeGa's Service Engineers can test and repair all of Teledyne's vacuum and flow products. These Teledyne factory-trained and certified technicians are capable of calibrating your instrument or repairing it quickly with genuine parts and up-to-date procedures as needed. Most calibration services are completed within 48 hours.&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;JeeGa has three calibration benches for MFMs/MFCs and one test stand for high vacuum calibration. The lab consists of multiple flow reference standards (Molbloc, DryCal, Teledyne), multiple vacuum reference standards (capacitance manometers), residual gas analyzers (RGA), helium leak detector and more.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture4-2.png?width=969&amp;amp;height=297&amp;amp;name=Picture4-2.png" width="969" height="297" alt="Picture4-2" style="height: auto; max-width: 100%; width: 969px;"&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;br&gt;Calibration&amp;nbsp;Capabilities:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 99%;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #ffffff;"&gt; 
  &lt;tbody&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 24.3734%; padding: 4px; border-color: #ffffff; text-align: left; background-color: #ffffff;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;Flow (Gas):&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 75.6737%; padding: 4px; border-color: #ffffff; background-color: #ffffff;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-size: 14px;"&gt;5 SCCM to 20 SLM (Fluke Molbox/Molbloc)&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-size: 14px;"&gt;10 SCCM to 50 SLM (DryCal)&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-size: 14px;"&gt;50 SLM to 1,000 SLM (Teledyne Hastings Instrument HFM-D-201B)&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 24.3734%; padding: 4px; border-color: #ffffff; background-color: #ffffff;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;Vacuum:&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 75.6737%; padding: 4px; border-color: #ffffff; background-color: #ffffff;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;span style="font-size: 14px;"&gt;1 x 10&lt;sup&gt;-7&lt;/sup&gt; Torr to 1,000 Torr (0.0000133 Pa to 133,322 Pa)&lt;/span&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture5-1.png?width=961&amp;amp;height=427&amp;amp;name=Picture5-1.png" width="961" height="427" alt="Picture5-1" style="height: auto; max-width: 100%; width: 961px;"&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;For more details about services offered by Shanghai JeeGa, please visit: &lt;a href="https://www.jeega.com.cn/"&gt;https://www.jeega.com.cn/&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;br&gt;Contact Details:&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Email: &lt;a href="mailto:wangxuemei@jeega.com.cn"&gt;wangxuemei@jeega.com.cn&lt;/a&gt;&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px; background-color: transparent;"&gt;Phone: +86 (21)-61179398&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px; background-color: transparent;"&gt;Address: Room 505, Building 18, 50 Smart Technology Park, No. 423 Wuning Road, Putuo District, Shanghai, 200063, China&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;For more information on calibration services for vacuum gauges, vacuum transducers, mass flow meters, and mass flow controllers provided by Teledyne Hastings Instruments, please check out: &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/calibration-repair"&gt;https://www.teledyne-hi.com/en-us/what-we-do/calibration-repair&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fservice-center-spotlight-shanghai-jeega-industrial-co.-ltd&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>Service Center Spotlight</category>
      <pubDate>Mon, 06 Oct 2025 15:43:02 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/service-center-spotlight-shanghai-jeega-industrial-co.-ltd</guid>
      <dc:date>2025-10-06T15:43:02Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>IP-67 Mass Flow Meters (MFM) and Mass Flow Controllers (MFC) for All Sizes</title>
      <link>https://info.teledyne-hi.com/blog/ip-67-mass-flow-meters-mfm-and-mass-flow-controllers-mfc-for-all-sizes</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/ip-67-mass-flow-meters-mfm-and-mass-flow-controllers-mfc-for-all-sizes" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/Picture1-2.png" alt="IP-67 Mass Flow Meters (MFM) and Mass Flow Controllers (MFC) for All Sizes" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt;</description>
      <content:encoded>&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture1-2.png?width=149&amp;amp;height=283&amp;amp;name=Picture1-2.png" width="149" height="283" alt="Picture1-2" style="height: auto; max-width: 100%; width: 149px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;span style="font-size: 12px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;&lt;span style="font-size: 14px;"&gt;Teledyne Hastings Instruments introduced the IP-67 Enclosure Version for our high accuracy Digital 300 Series of thermal mass flow meters and flow controllers in 2018. The IP, or Ingress Protection rating, describes the instrument’s ability to operate in challenging environments. The first number, 6, indicates that the flow instrument has total protection against dust (particulate). That’s the highest-level of dust protection achievable under the IP Code. The second number, 7, refers to protection from liquids.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;The Digital 300 Series with optional IP-67 enclosure can withstand water immersion up to one (1) meter for thirty (30) minutes. While it may not be obvious to everyone, it offers the liquid protection of the one meter / thirty-minute immersion as well as all lesser liquid codes (from dripping water through powerful water jets).&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture2-2.png?width=264&amp;amp;height=144&amp;amp;name=Picture2-2.png" width="264" height="144" alt="Picture2-2" style="height: auto; max-width: 100%; width: 264px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;For more specific details on IP-67 and Ingress Protection ratings, please see our previous blog: &lt;a href="https://info.teledyne-hi.com/blog/digital-flow-meters-and-controllers-now-protected-against-dust-and-water-what-that-means-for-you"&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;Digital Flow Meters and Controllers now protected against dust and water - what that means for you!&lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px;"&gt;&lt;span style="font-size: 14px;"&gt;What are the benefits of a mass flow meter (MFM) or mass flow controller (MFC) with IP-67 rating? It’s two-fold:&lt;/span&gt;&lt;/p&gt; 
&lt;ol&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Employee safety is every employer’s primary concern. IP-67 enclosures help to protect your employees from making accidental contact with hazardous electrical components and potential electrical shock.&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;IP-67 enclosures also help protect your equipment from the ingress of solid particles and/or liquids. Most MFC enclosures contain a PCB assembly, thermal flow sensor, and a proportional control valve. By protecting your MFC from particulate contamination and/or moisture, you prolong the service-life of those components.&lt;/span&gt;&lt;br&gt;&lt;br&gt;&lt;br&gt;&lt;/li&gt; 
&lt;/ol&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture3.jpg?width=150&amp;amp;height=98&amp;amp;name=Picture3.jpg" width="150" height="98" alt="Picture3" style="height: auto; max-width: 100%; width: 150px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;This protection against dust and liquids makes IP-67 MFCs ideal for demanding indoor and outdoor applications. Whether it’s a heavy-dust industrial environment or in a facility with routine sanitary washdown requirements, the Teledyne Hastings Instruments Digital 300 Series IP-67 MFCs endure.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;Common applications include:&lt;/span&gt;&lt;/p&gt; 
&lt;ul&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Food and Beverage&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Heat Treating/Metals Processing&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Environmental Monitoring&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Biotech/Pharmaceutical&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Chemical/Petrochemical&lt;/span&gt;&lt;/li&gt; 
 &lt;li&gt;&lt;span style="font-size: 14px;"&gt;Gas Distribution&lt;/span&gt;&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture4-1.png?width=142&amp;amp;height=128&amp;amp;name=Picture4-1.png" width="142" height="128" alt="Picture4-1" style="height: auto; max-width: 100%; width: 142px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;All internal components of the Digital 300 Series IP-67 MFMs and MFCs are either gasket or o-ring sealed for ingress protection. The electronics interface uses a 12-pin circular connector that facilitates Power (24vdc, Common, and Ground), Analog Input / Output (0-5vdc, 0-10vdc, 4-20mA, or 0-20mA), and Digital Communication (RS232 or RS485).&amp;nbsp;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 14px;"&gt;All Digital 300 Series models (sizes) are available with the IP-67 option. These sizes combine to offer complete coverage from a minimum Full Scale flow rate of 5 sccm up to a maximum Full Scale flow rate of 10,000 SLM of N2 or equivalent. Selection details for each model are illustrated in this table:&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 100%; margin-left: auto; margin-right: auto;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2;"&gt; 
  &lt;tbody&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 10.4101%; padding: 4px;"&gt;&lt;strong&gt;&lt;span style="font-size: 12px;"&gt;Size&lt;/span&gt;&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 16.7192%; padding: 4px;"&gt;&lt;strong&gt;&lt;span style="font-size: 12px;"&gt;MFM Model&lt;/span&gt;&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 17.3502%; padding: 4px;"&gt;&lt;strong&gt;&lt;span style="font-size: 12px;"&gt;MFC Model&lt;/span&gt;&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0343%; padding: 4px;"&gt;&lt;strong&gt;&lt;span style="font-size: 12px;"&gt;Nominal Tubing&lt;/span&gt;&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0288%; padding: 4px;"&gt;&lt;strong&gt;&lt;span style="font-size: 12px;"&gt;Maximum Flow (N2 Equiv.)&lt;/span&gt;&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 15.142%; padding: 4px;"&gt;&lt;strong&gt;&lt;span style="font-size: 12px;"&gt;IP-67 Option&lt;/span&gt;&lt;/strong&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 10.4101%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;S&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 16.7192%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFM-D-300A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 17.3502%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFC-D-302A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0343%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;1/8" and 1/4"&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0288%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;25 SLM&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 15.142%; padding-top: 4px; padding-right: 4px; padding-bottom: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hubfs/Green%20Check.svg" width="23" height="23" alt="Green Check" style="height: auto; max-width: 100%; width: 23px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 10.4101%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;M&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 16.7192%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFM-D-301A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 17.3502%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFC-D-303A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0343%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;1/2" and 3/4"&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0288%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;1,000 SLM&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 15.142%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hubfs/Green%20Check.svg" width="23" height="23" alt="Green Check" style="height: auto; max-width: 100%; width: 23px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 10.4101%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;L&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 16.7192%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFM-D-305A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 17.3502%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFC-D-307A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0343%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;1"&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0288%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;3,000 SLM&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 15.142%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hubfs/Green%20Check.svg" width="23" height="23" alt="Green Check" style="height: auto; max-width: 100%; width: 23px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 10.4101%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;XL&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 16.7192%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFC-D-306A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 17.3502%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;HFC-D-308A&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0343%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;2"&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.0288%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;10,000 SLM&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 15.142%; padding: 4px;"&gt;&lt;span style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hubfs/Green%20Check.svg" width="23" height="23" alt="Green Check" style="height: auto; max-width: 100%; width: 23px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 14px;"&gt;Most features of the Digital 300 Series MFMs and MFCs are supported by the IP-67 version. These include the totalizer, valve over-ride, soft start, fold-over protection and many more.&lt;/p&gt; 
&lt;p style="font-size: 14px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;Visit &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/thermal-mass-flow"&gt;&lt;span style="color: #0070c0;"&gt;https://www.teledyne-hi.com/en-us/what-we-do/thermal-mass-flow&lt;/span&gt;&lt;/a&gt; to learn more about Teledyne Hastings Instruments mass flow meters and mass flow controllers.&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;If you have questions about mass flow controllers, feel free to contact us by phone (+1-757-723-6531 or 1-800-950-2468), email &lt;a href="mailto:Hastings_Instruments@Teledyne.com"&gt;Hastings_Instruments@Teledyne.com&lt;/a&gt;, or via Live Chat on our website &lt;a href="http://www.teledyne-hi.com"&gt;www.teledyne-hi.com&lt;/a&gt;.&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fip-67-mass-flow-meters-mfm-and-mass-flow-controllers-mfc-for-all-sizes&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>mass flow controller</category>
      <category>mass flow meter</category>
      <category>mass flow instruments</category>
      <category>IP-67</category>
      <pubDate>Thu, 11 Sep 2025 20:49:30 GMT</pubDate>
      <author>hastings_instruments@teledyne.com (The Teledyne Hastings Team)</author>
      <guid>https://info.teledyne-hi.com/blog/ip-67-mass-flow-meters-mfm-and-mass-flow-controllers-mfc-for-all-sizes</guid>
      <dc:date>2025-09-11T20:49:30Z</dc:date>
    </item>
    <item>
      <title>Service Center Spotlight: InfoRAD Corp.</title>
      <link>https://info.teledyne-hi.com/blog/service-center-spotlight-inforad-corp</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/service-center-spotlight-inforad-corp" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/Spotlight%20-%20infoRAD.png" alt="InfoRAD Service Center Spotlight Graphic" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;pre style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;/span&gt;&lt;/pre&gt; 
&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;br&gt;This is the second blog in our series highlighting Teledyne Hastings Instruments’ authorized service partners. These partners are fully authorized to calibrate and repair Teledyne Hastings Instruments’ vacuum gauges, mass flow meters (MFMs), and mass flow controllers (MFCs).&lt;/span&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;pre style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Spotlight%20-%20infoRAD.png?width=572&amp;amp;height=290&amp;amp;name=Spotlight%20-%20infoRAD.png" width="572" height="290" alt="Spotlight - infoRAD" style="height: auto; max-width: 100%; width: 572px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/span&gt;&lt;/pre&gt; 
&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;br&gt;This is the second blog in our series highlighting Teledyne Hastings Instruments’ authorized service partners. These partners are fully authorized to calibrate and repair Teledyne Hastings Instruments’ vacuum gauges, mass flow meters (MFMs), and mass flow controllers (MFCs).&lt;/span&gt;&lt;/p&gt;  
&lt;p style="font-size: 12px; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Logo.png?width=213&amp;amp;height=59&amp;amp;name=Logo.png" width="213" height="59" alt="Logo" style="height: auto; max-width: 100%; width: 213px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;This service partner provides calibration and repair service for the Republic of Korea as well as the large Asia-Pacific region (excluding China). Let’s meet InfoRAD!&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture1-1.png?width=221&amp;amp;height=143&amp;amp;name=Picture1-1.png" width="221" height="143" alt="Picture1-1" style="height: auto; max-width: 100%; width: 221px; float: right; margin: 0px 0px 1px 15px;"&gt;InfoRAD Corp. was a part of Applied Engineering which became a distributor for Teledyne Hastings&amp;nbsp;Instruments in 1983. Applied Engineering decided to spin-off InfoRAD in 2003, and InfoRAD immediately began the transition from a pure sales office to a complete sales, calibration, repair, and custom system design facility. They support customers across South Korea from their headquarters in the M-City Tower in Goyang. The office sits on Seoul’s northwest edge which is only 30 minutes to downtown Seoul and about 40 minutes to Incheon International Airport via expressway or airport rail. This convenient location facilitates fast deliveries, quick on-site visits, and smooth travel for visiting engineers. InfoRAD stocks vacuum gauges, vacuum transducers, mass flow meters (MFMs), and mass flow controllers (MFCs). This means you don’t have to wait for long overseas shipments.&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 72%; margin-left: auto; margin-right: auto;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #000000; height: 146px;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 26px;"&gt; 
    &lt;td style="width: 21.5034%; padding: 4px; background-color: #0076c0; border-color: #000000; height: 26px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #ffffff;"&gt;Category&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 78.4645%; padding: 4px; background-color: #0076c0; border-color: #000000; height: 26px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;span style="color: #ffffff;"&gt;Products Stocked in Korea&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 60px;"&gt; 
    &lt;td style="width: 21.5034%; padding: 4px; border-color: #000000; height: 60px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Flow&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 78.4645%; padding: 4px; border-color: #000000; height: 60px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;HFM-200, HFC-202, HFM-D-300B, HFM-D-301B, &lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;HFC-D-302B,&amp;nbsp;HFC-D-303B, THCD-101&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 60px;"&gt; 
    &lt;td style="width: 21.5034%; padding: 4px; border-color: #000000; height: 60px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Vacuum&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 78.4645%; padding: 4px; border-color: #000000; height: 60px; border-style: solid;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;HVG-2020B, DAVC, DCVT, VT-6A, HPM 4/5/6, DB-20, DV-6R, DV-6-VCR, DV-6-KF-25, DV-5M, DV-5S&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;InfoRAD has Teledyne factory-trained and certified technicians capable of calibrating your instrument or repairing it quickly with genuine parts and up-to-date procedures as needed. InfoRAD has a complete laboratory with flow reference standards, vacuum reference standards, helium leak detector, and more.&amp;nbsp;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;Do you have too many instruments to ship?&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;span style="font-weight: bold;"&gt;&lt;/span&gt;The InfoRAD team will travel anywhere in Korea with portable standards and tools.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture2-1.png?width=593&amp;amp;height=238&amp;amp;name=Picture2-1.png" width="593" height="238" alt="Picture2-1" style="height: auto; max-width: 100%; width: 593px; margin-left: auto; margin-right: auto; display: block;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;&lt;br&gt;Calibration&amp;nbsp;Capabilities:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 68%;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2; border-color: #ffffff;"&gt; 
  &lt;tbody&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 24.3592%; padding: 4px; border-color: #ffffff; text-align: left; background-color: #ffffff;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;Flow (Gas):&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 75.6879%; padding: 4px; border-color: #ffffff; background-color: #ffffff;"&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;In-house lab: 10 sccm to 100 SLM&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;On-site service: 10 sccm to 3,000 SLM&lt;/span&gt;&lt;/p&gt; &lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr&gt; 
    &lt;td style="width: 24.3592%; padding: 4px; border-color: #ffffff; background-color: #ffffff;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;Vacuum:&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 75.6879%; padding: 4px; border-color: #ffffff; background-color: #ffffff;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;1 mTorr to 1,000 Torr (0.133 Pa to 133,322 Pa)&lt;/span&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;strong&gt;Custom Flow and Vacuum Projects&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;From small flow and vacuum setups for universities and research labs to large gas delivery systems, gas mixing systems, and flow measurement test stands, InfoRAD engineers can design one-off systems built exactly to a customer’s specifications. Custom software and interfaces are also available.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture3-1.png?width=1416&amp;amp;height=469&amp;amp;name=Picture3-1.png" width="1416" height="469" alt="Picture3-1" style="height: auto; max-width: 100%; width: 1416px;"&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;For more details about services offered by InfoRAD, please visit: &lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;&lt;a href="https://en.inforad.co.kr/"&gt;https://en.inforad.co.kr/&lt;/a&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Contact Details:&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Email: &lt;a href="mailto:info@inforad.co.kr"&gt;info@inforad.co.kr&lt;/a&gt;&lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Phone: +82-70-4640-2580&lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;Address: #11007, Section-Bldg, M-City Tower, 195 Baengma-ro, Goyang-si, Gyeonggi-do 10403, South Korea&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif; font-size: 14px;"&gt;For more information on calibration services for vacuum gauges, vacuum transducers, mass flow meters, and mass flow controllers provided by Teledyne Hastings Instruments, please check out: &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/calibration-repair"&gt;https://www.teledyne-hi.com/en-us/what-we-do/calibration-repair&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fservice-center-spotlight-inforad-corp&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>Service Center Spotlight</category>
      <pubDate>Wed, 09 Jul 2025 15:10:55 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/service-center-spotlight-inforad-corp</guid>
      <dc:date>2025-07-09T15:10:55Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>Replacing the CVT Vacuum Controller with the DCVT</title>
      <link>https://info.teledyne-hi.com/blog/replacing-the-cvt-vacuum-controller-with-the-dcvt</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/replacing-the-cvt-vacuum-controller-with-the-dcvt" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/CVT%20v%20DCVT.png" alt="Replacing the CVT Vacuum Controller with the DCVT" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 35%; margin-left: 10px; margin-right: 0px; float: right;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px none #99acc2;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 50px;"&gt; 
    &lt;td style="width: 50.0564%; padding: 4px; height: 50px; text-align: center; border-width: 0px; border-style: none; vertical-align: bottom;"&gt; &lt;p&gt;Model CVT-26A&lt;/p&gt; &lt;/td&gt; 
    &lt;td style="width: 50.0564%; padding: 4px; height: 50px; text-align: center;"&gt; &lt;p&gt;Model DCVT-6&lt;/p&gt; &lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="text-align: justify; font-size: 12px;"&gt;Teledyne Hastings Instruments manufactured several variations of the dependable model CVT vacuum controller for multiple decades. While they are obsolete now, a replacement is available. In most cases, the current model DCVT can fulfill the functions of your CVT.&lt;/p&gt; 
&lt;p style="text-align: justify; font-size: 12px;"&gt;The CVT was more than a basic vacuum gauge. It was a vacuum controller with setpoints and relays. You could use it to control a pump, a valve, an alarm, an indicator light, or almost any electrical device. The DCVT is also a vacuum controller, but it offers many more features. While the DCVT is dimensionally different and does look quite different, it still uses the same Teledyne Hastings Instruments’ DV Series thermocouple gauge tubes as the CVT. Whether you are using DV-4, DV-5, or DV-6 Series thermocouple gauge tubes, they will all work with the DCVT.&lt;/p&gt; 
&lt;p style="text-align: justify; font-size: 12px;"&gt;The following sections will assist you in replacing your CVT with the DCVT.&lt;/p&gt;</description>
      <content:encoded>&lt;div style="overflow-x: auto; max-width: 100%; width: 35%; margin-left: 10px; margin-right: 0px; float: right;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px none #99acc2;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 50px;"&gt; 
    &lt;td style="width: 50.0564%; padding: 4px; height: 50px; text-align: center; border-width: 0px; border-style: none; vertical-align: bottom;"&gt; &lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/CVT.gif?width=67&amp;amp;height=67&amp;amp;name=CVT.gif" width="67" height="67" alt="CVT" style="height: auto; max-width: 100%; width: 67px;"&gt;&lt;/p&gt; &lt;p&gt;Model CVT-26A&lt;/p&gt; &lt;/td&gt; 
    &lt;td style="width: 50.0564%; padding: 4px; height: 50px; text-align: center;"&gt; &lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/DCVT%20No%20Background.jpg?width=116&amp;amp;height=67&amp;amp;name=DCVT%20No%20Background.jpg" width="116" height="67" alt="DCVT No Background" style="height: auto; max-width: 100%; width: 116px;"&gt;&lt;/p&gt; &lt;p&gt;Model DCVT-6&lt;/p&gt; &lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p style="text-align: justify; font-size: 12px;"&gt;Teledyne Hastings Instruments manufactured several variations of the dependable model CVT vacuum controller for multiple decades. While they are obsolete now, a replacement is available. In most cases, the current model DCVT can fulfill the functions of your CVT.&lt;/p&gt; 
&lt;p style="text-align: justify; font-size: 12px;"&gt;The CVT was more than a basic vacuum gauge. It was a vacuum controller with setpoints and relays. You could use it to control a pump, a valve, an alarm, an indicator light, or almost any electrical device. The DCVT is also a vacuum controller, but it offers many more features. While the DCVT is dimensionally different and does look quite different, it still uses the same Teledyne Hastings Instruments’ DV Series thermocouple gauge tubes as the CVT. Whether you are using DV-4, DV-5, or DV-6 Series thermocouple gauge tubes, they will all work with the DCVT.&lt;/p&gt; 
&lt;p style="text-align: justify; font-size: 12px;"&gt;The following sections will assist you in replacing your CVT with the DCVT.&lt;/p&gt; 
&lt;p&gt;&lt;span style="color: #0076c0; font-family: arial, helvetica; font-size: 18px; background-color: transparent;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-family: arial, helvetica; font-size: 18px; background-color: transparent; color: #0076c0;"&gt;Choose the appropriate gauge:&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;To choose the appropriate gauge, select the one that corresponds to your thermocouple gauge tube series. Most are color coded for quick identification.&lt;/p&gt; 
&lt;div style="overflow-x: auto; max-width: 100%; width: 79%; margin-left: 0px; margin-right: 10px; float: left;"&gt; 
 &lt;table style="width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2; height: 97px;"&gt; 
  &lt;tbody&gt; 
   &lt;tr style="height: 25px;"&gt; 
    &lt;td style="width: 11.7849%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;strong&gt;Series&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 16.1793%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;strong&gt;Color Code&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 20.7734%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;strong&gt;Nominal Range&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 32.9518%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;strong&gt;Obsolete CVT Models&lt;/strong&gt;&lt;/td&gt; 
    &lt;td style="width: 18.3824%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;strong&gt;DCVT Model&lt;/strong&gt;&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 25px;"&gt; 
    &lt;td style="width: 11.7849%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;DV-4&lt;/td&gt; 
    &lt;td style="width: 16.1793%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;span style="background-color: #ffffff; color: #9a00ff;"&gt;Purple&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.7734%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;20 Torr&lt;/td&gt; 
    &lt;td style="width: 32.9518%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;CVT-14, CVT-24 or CVT-24A&lt;/td&gt; 
    &lt;td style="width: 18.3824%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;DCVT-4&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 25px;"&gt; 
    &lt;td style="width: 11.7849%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;DV-5&lt;/td&gt; 
    &lt;td style="width: 16.1793%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;&lt;span style="color: #ff0201;"&gt;Red&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.7734%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;100 mTorr&lt;/td&gt; 
    &lt;td style="width: 32.9518%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;CVT-15A or CVT-25A&lt;/td&gt; 
    &lt;td style="width: 18.3824%; padding: 4px; height: 25px; border-width: 1px; border-style: solid;"&gt;DCVT-5&lt;/td&gt; 
   &lt;/tr&gt; 
   &lt;tr style="height: 22px;"&gt; 
    &lt;td style="width: 11.7849%; padding: 4px; height: 22px; border-width: 1px; border-style: solid;"&gt;DV-6&lt;/td&gt; 
    &lt;td style="width: 16.1793%; padding: 4px; height: 22px; border-width: 1px; border-style: solid;"&gt;&lt;span style="color: #f1c233;"&gt;Yellow&lt;/span&gt;&lt;/td&gt; 
    &lt;td style="width: 20.7734%; padding: 4px; height: 22px; border-width: 1px; border-style: solid;"&gt;1,000 mTorr&lt;/td&gt; 
    &lt;td style="width: 32.9518%; padding: 4px; height: 22px; border-width: 1px; border-style: solid;"&gt;CVT-16, CVT-26 or CVT-26A&lt;/td&gt; 
    &lt;td style="width: 18.3824%; padding: 4px; height: 22px; border-width: 1px; border-style: solid;"&gt;DCVT-6&lt;/td&gt; 
   &lt;/tr&gt; 
  &lt;/tbody&gt; 
 &lt;/table&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Tube-Colors.jpg?width=107&amp;amp;height=107&amp;amp;name=Tube-Colors.jpg" width="107" height="107" alt="Tube-Colors" style="height: auto; max-width: 100%; width: 107px;"&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal;"&gt;&lt;span style="color: #0076c0;"&gt;Dial Face vs Digital Display:&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-weight: normal; text-align: justify;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/dial%20face%20v%20digital%20display.png?width=317&amp;amp;height=141&amp;amp;name=dial%20face%20v%20digital%20display.png" width="317" height="141" alt="dial face v digital display" style="height: auto; max-width: 100%; width: 317px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;span style="font-size: 12px;"&gt;The obvious difference between the CVT and DCVT are their displays. The CVT provided a dial-face with needle movement. Some users liked to see the needle movement because the movement rate gave them a feel for their vacuum system’s performance. It also provided a quick-read indication when looking from across a room. While the DCVT does not have the dial-face and needle, it does provide a bright and easy-to-read digital display. The DCVT setpoints for the relays are still accessible from the front panel just as they were on the CVT.&amp;nbsp;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-weight: normal; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal;"&gt;&lt;span style="color: #0076c0;"&gt;Dimensions:&lt;/span&gt;&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;Can you fit a square peg in a round hole? For panel mounted gauges, it’s not as difficult as it sounds. If your CVT was panel mounted, you will likely choose to fabricate a new panel or an adapter panel. If you had the gauge resting on a tabletop, it won’t be an issue.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/dimensions.png?width=1395&amp;amp;height=760&amp;amp;name=dimensions.png" width="1395" height="760" alt="dimensions" style="height: auto; max-width: 100%; width: 1395px;"&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt; 
&lt;h2&gt;&lt;strong&gt;&lt;span style="color: #0070c0;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/communications.png?width=136&amp;amp;height=175&amp;amp;name=communications.png" width="136" height="175" alt="communications" style="height: auto; max-width: 100%; width: 136px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h2&gt; 
&lt;h2&gt;&lt;span style="font-weight: normal; color: #0076c0;"&gt;Output Signal / Communication:&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-size: 12px;"&gt;The DCVT offers the exact same nonlinear 0-1vdc output curve that was standard on the CVT. In addition, the DCVT offers optional output signals of 0-1vdc linear, 0-5vdc linear, 0-10vdc linear, 4-20mA linear, and 0-20 mA linear.&lt;/p&gt; 
&lt;p style="font-size: 12px;"&gt;The DCVT also provides RS232 communication. A certified LabVIEW driver is available.&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal;"&gt;&lt;span style="color: #0076c0;"&gt;Terminal Strip Comparison:&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-size: 12px;"&gt;The terminal strips look different, but all CVT connections are available on the DCVT. It also gives you the choice of AC input power or DC input power.&lt;/p&gt; 
&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/terminal%20strip.png?width=1403&amp;amp;height=543&amp;amp;name=terminal%20strip.png" width="1403" height="543" alt="terminal strip" style="height: auto; max-width: 100%; width: 1403px;"&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal;"&gt;&lt;span style="color: #0076c0;"&gt;Common Applications:&lt;/span&gt;&lt;/h2&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;Common Applications for the DCVT (and obsolete CVT) include Vacuum Metallurgy, Vacuum Coating, Vacuum Furnace, Refrigeration (HVAC), Freeze Drying, Lighting Manufacturing, Power/Transformer Maintenance, Cryogenic/Vacuum Insulation, and more.&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;To learn more about the Teledyne Hastings Instruments Model DCVT Vacuum Controller, visit &lt;a href="https://www.teledyne-hi.com/en-us/What-we-do_/Documents/Bulletins/PB-182_Digital%20CVT%20%26%20VT.pdf"&gt;&lt;span style="color: #0070c0;"&gt;&lt;span style="color: #3574e3;"&gt;https://www.teledyne-hi.com/en-us/What-we-do_/Documents/Bulletins/PB-182_Digital%20CVT%20%26%20VT.pdf&lt;/span&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p&gt;&lt;span style="font-size: 12px;"&gt;If you have questions about vacuum gauges or vacuum controllers, feel free to contact us by phone (+1-757-723-6531 or 1-800-950-2468), email &lt;a href="mailto:Hastings_Instruments@Teledyne.com"&gt;&lt;span style="color: #3574e3;"&gt;Hastings_Instruments@Teledyne.com&lt;/span&gt;&lt;/a&gt;, or via Live Chat on our website &lt;span style="color: #3574e3;"&gt;&lt;a href="http://www.teledyne-hi.com" style="color: #3574e3;"&gt;www.teledyne-hi.com&lt;/a&gt;&lt;/span&gt;.&lt;/span&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Freplacing-the-cvt-vacuum-controller-with-the-dcvt&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Tue, 24 Jun 2025 15:10:35 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/replacing-the-cvt-vacuum-controller-with-the-dcvt</guid>
      <dc:date>2025-06-24T15:10:35Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>MFC Pressure Specifications: Why are there so many?</title>
      <link>https://info.teledyne-hi.com/blog/mfc-pressure-specifications</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/mfc-pressure-specifications" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/300Vue.jpg" alt="Model 300Vue" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;Thermal Mass Flow Controllers (MFCs) control the mass flow (or more specifically molecular flow) of gases. If we&amp;nbsp;are measuring flow rates, why are there so may pressure specifications? This blog will attempt to explain the various pressure specifications associated with MFCs.&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;&lt;/h2&gt;</description>
      <content:encoded>&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/300Vue.jpg?width=100&amp;amp;height=107&amp;amp;name=300Vue.jpg" width="100" height="107" alt="300Vue" style="height: auto; max-width: 100%; width: 100px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;Thermal Mass Flow Controllers (MFCs) control the mass flow (or more specifically molecular flow) of gases. If we&amp;nbsp;are measuring flow rates, why are there so may pressure specifications? This blog will attempt to explain the various pressure specifications associated with MFCs.&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;&lt;/h2&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;Standard Temperature and Pressure (or STP):&lt;/h2&gt; 
&lt;p style="font-weight: normal;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture1.png?width=196&amp;amp;height=150&amp;amp;name=Picture1.png" width="196" height="150" alt="Picture1" style="height: auto; max-width: 100%; width: 196px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;span style="font-size: 12px;"&gt;The volume of a gas changes with temperature and pressure changes; therefore, basic volumetric flow units are almost useless when defining gas flow rates. When you pick up an MFC or look at the calibration report, you always find a value for Standard Temperature and Pressure (or STP. For most MFC applications, it will be listed as &lt;span style="font-weight: bold;"&gt;STP: 0° C &amp;amp; 760 Torr.&lt;/span&gt; This does &lt;u&gt;not&lt;/u&gt; mean that the MFC must be used at that temperature and pressure. Some gases may not even be in gas phase at those conditions. STP is a way of defining molar volumetric units. STP allows your gas calculations to be correct when you measure all your experimental data using the same STP values.&lt;/span&gt;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;Maximum Allowable Working Pressure:&lt;/h2&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture2.jpg?width=141&amp;amp;height=46&amp;amp;name=Picture2.jpg" width="141" height="46" alt="Picture2" style="height: auto; max-width: 100%; width: 141px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/h2&gt; 
&lt;p style="font-weight: normal;"&gt;&lt;span style="font-size: 12px;"&gt;The Maximum Allowable Working Pressure (sometimes expressed as M.A.W.P.) represents the maximum working&amp;nbsp;pressure for which the end user is permitted to operate the MFC. There should be a label on the MFC that defines this value. For safety purposes, the end user should never exceed this limit.&lt;/span&gt;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;Proof Pressure:&lt;/h2&gt; 
&lt;p style="font-weight: normal;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture3.png?width=108&amp;amp;height=136&amp;amp;name=Picture3.png" width="108" height="136" alt="Picture3" style="height: auto; max-width: 100%; width: 108px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;br&gt;&lt;span style="font-size: 12px;"&gt;The Proof Pressure is the pressure value to which the MFC manufacturer proof tests the unit. This value is typically 1.5 times the Maximum Allowable Working Pressure. For example: if the Maximum Allowable Working Pressure is 500 PSIG, the manufacture may Proof Test the unit to 750 PSIG. Even though the manufacturer tests the unit to this value, the end user is still not permitted to exceed the Maximum Allowable Working Pressure.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-weight: normal;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;Burst Pressure:&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture4.png?width=190&amp;amp;height=148&amp;amp;name=Picture4.png" width="190" height="148" alt="Picture4" style="height: auto; max-width: 100%; width: 190px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/h2&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;B&lt;span style="background-color: transparent;"&gt;urst Pressure is the maximum pressure that can possibly be applied to the MFC without physical damage to the pressure containment. It’s typically much higher than the Proof Pressure. MFC manufacturers will define this during product development. This can be modelled using 3D stress analysis and eventually tested using a hydraulic pump. Burst Pressure testing tends to be a favorite for most engineers.&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;&lt;span style="background-color: transparent;"&gt;Inlet Pressure &amp;amp; Outlet Pressure:&lt;/span&gt;&lt;/h2&gt; 
&lt;p style="font-weight: normal;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture5.png?width=222&amp;amp;height=65&amp;amp;name=Picture5.png" width="222" height="65" alt="Picture5" style="height: auto; max-width: 100%; width: 222px; float: left; margin-left: 0px; margin-right: 10px;"&gt;&lt;span style="font-size: 12px;"&gt;Some people forget that the MFC contains a proportional control valve. To proportionally control the flow, there must be a pressure drop across the MFC. Inlet Pressure (Up Stream Pressure) is the pressure measured exactly at the MFC inlet fitting. Outlet Pressure (Down Stream Pressure) is the pressure measured exactly at the MFC outlet fitting. To facilitate flow, Inlet Pressure must always be greater than Outlet Pressure. Some MFC manufacturers will define these values on the MFC Serial Number label.&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;Differential Pressure&lt;/h2&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;Differential Pressure is often abbreviated as dP or ΔP.&lt;/p&gt; 
&lt;p style="padding-left: 40px; font-weight: bold; font-size: 12px;"&gt;dP = Inlet Pressure – Outlet Pressure&lt;br&gt;&lt;br&gt;&lt;/p&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;Pressure Coefficients:&lt;/h2&gt; 
&lt;h2 style="font-weight: normal; font-size: 16px;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture6-1.png?width=149&amp;amp;height=98&amp;amp;name=Picture6-1.png" width="149" height="98" alt="Picture6-1" style="height: auto; max-width: 100%; width: 149px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/h2&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;Even though thermal mass flow values are independent of temperature and pressure changes, the thermal mass flow sensor performance is impacted at higher pressures. The flow sensor consists of a small 316SS capillary tube that is wrapped with several windings of heater wire. When the pressure increases, the capillary tube expands. When that occurs, the heater windings expand with the tube. The error associated with this expansion is represented by the Pressure Coefficient. For example, a typical Pressure Coefficient could be +0.0067%/psi.&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal; font-size: 12px;"&gt;To learn more about the Teledyne Hastings Instruments mass flow meters and mass flow controllers, visit &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/thermal-mass-flow"&gt;https://www.teledyne-hi.com/en-us/what-we-do/thermal-mass-flow&lt;/a&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-weight: normal;"&gt;&lt;span style="font-size: 12px;"&gt;If you have questions about mass flow controllers, feel free to contact us by phone (+1-757-723-6531 or 1-800-950-2468), email &lt;a href="mailto:Hastings_Instruments@Teledyne.com"&gt;Hastings_Instruments@Teledyne.com&lt;/a&gt;, or via Live Chat on our website &lt;a href="http://www.teledyne-hi.com/en-us"&gt;www.teledyne-hi.com&lt;/a&gt;.&lt;/span&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fmfc-pressure-specifications&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Thu, 29 May 2025 19:45:24 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/mfc-pressure-specifications</guid>
      <dc:date>2025-05-29T19:45:24Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>Service Center Spotlight: Chell Instruments, Ltd.</title>
      <link>https://info.teledyne-hi.com/blog/service-center-spotlight-chell-instruments-ltd</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/service-center-spotlight-chell-instruments-ltd" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/Spotlight%20-%20Chell-1.png" alt="Chell Instruments Logo" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;pre style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;/pre&gt; 
&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;We are starting a new blog series where we will introduce you to our authorized service partners. These partners are fully authorized to calibrate and repair Teledyne Hastings Instruments products.&lt;/span&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;pre style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Spotlight%20-%20Chell-1.png?width=511&amp;amp;height=259&amp;amp;name=Spotlight%20-%20Chell-1.png" width="511" height="259" alt="Spotlight - Chell-1" style="height: auto; max-width: 100%; width: 511px; margin-left: auto; margin-right: auto; display: block;"&gt;&lt;/pre&gt; 
&lt;p style="font-size: 16px; font-weight: bold;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;We are starting a new blog series where we will introduce you to our authorized service partners. These partners are fully authorized to calibrate and repair Teledyne Hastings Instruments products.&lt;/span&gt;&lt;/p&gt;  
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Chell%20Logo.png?width=193&amp;amp;height=66&amp;amp;name=Chell%20Logo.png" width="193" height="66" alt="Chell Logo" style="height: auto; max-width: 100%; width: 193px; float: right; margin: 0px 0px 0px 15px;"&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Our first blog in this series will focus on the EMEA (Europe-Middle East-Africa) Service Center, Chell Instruments. Chell is based in North Walsham, England which is on the east coast near Norwich, about a 3-hour drive northeast of London.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;br&gt;Chell Instruments was established in May of 1976 by Ron and Judith Michell, hence the name Chell. They became a distributor for Teledyne Hastings Instruments shortly after in 1977 and began to distribute Hastings’ vacuum gauges, mass flow meters, and mass flow controllers in the United Kingdom and Ireland. Not only is Chell a great distributor, but they also excel at designing and manufacturing their own products and systems. In fact, they have a full engineering team that allows them to provide turnkey system solutions for their customers.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;br&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture1.jpg?width=249&amp;amp;height=138&amp;amp;name=Picture1.jpg" width="249" height="138" alt="Picture1" style="height: auto; max-width: 100%; width: 249px; margin: 0px 15px 0px 0px; float: left;"&gt;The last component to Chell’s success (and the topic of this blog) is their extensive calibration lab. Chell operates a complete calibration and repair lab capable of servicing instruments that measure Flow (Gas), Vacuum, Pressure, Temperature, and Electrical properties. Chell’s lab is UKAS accredited (fully accredited to ISO/IEC17025:2017). Chell can calibrate and repair nearly all Teledyne Hastings Instruments vacuum gauges, mass flow meters, and mass flow controllers. They also stock spare parts in England to quickly support most mass flow meter and mass flow controller repairs.&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;CALIBRATION Capabilities:&lt;br&gt;&lt;/strong&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Flow (Gas):&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 0.0010 L/min to 1250 L/min (up to 7 bar); Up to 12,500 L/min (at low pressure)&lt;br&gt;&lt;/span&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Vacuum:&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 1x10&lt;sup&gt;-4&lt;/sup&gt; Pa / 1x10&lt;sup&gt;-6&lt;/sup&gt; mbar / 7.5x10&lt;sup&gt;-7&lt;/sup&gt; Torr to 1000 Torr&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;strong&gt;Complete details can be found at: &lt;/strong&gt;&lt;a href="https://chell.co.uk/calibration"&gt;&lt;strong&gt;https://chell.co.uk/calibration&lt;/strong&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;One of the great attributes of Chell is their flexibility. If you have too many instruments to ship to Chell, they will come to you! They offer on-site calibration services for several ranges of instruments, and they offer this service for most of the United Kingdom. Would you like to calibrate your own vacuum gauges? If so, Chell sells a portable vacuum calibration system called the CalCube. Would you like to calibrate your own mass flow meters and mass flow controllers? If so, Chell sells flow calibration standards (Fluke Molbox/Molbloc) and can even manufacture complete flow calibration systems.&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Picture2.png?width=929&amp;amp;height=249&amp;amp;name=Picture2.png" width="929" height="249" alt="Picture2" style="height: auto; max-width: 100%; width: 929px;"&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;For more details about services offered by Chell Instruments, please visit: &lt;a href="https://chell.co.uk"&gt;https://chell.co.uk&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;Also, be sure to follow Chell on LinkedIn to stay on top of what’s new. Next year will mark Chell’s 50th anniversary, so stay tuned for their big celebration!&lt;/span&gt;&lt;br&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;&lt;a href="https://www.linkedin.com/company/chell-instruments"&gt;https://www.linkedin.com/company/chell-instruments&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&lt;span style="font-family: Arial, Helvetica, sans-serif;"&gt;For more information on calibration services for vacuum gauges, vacuum transducers, mass flow meters, and mass flow controllers provided by Teledyne Hastings Instruments, please check out: &lt;a href="https://www.teledyne-hi.com/en-us/what-we-do/calibration-repair"&gt;https://www.teledyne-hi.com/en-us/what-we-do/calibration-repair&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p style="font-size: 14px; line-height: 1.25; text-align: justify;"&gt;&amp;nbsp;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fservice-center-spotlight-chell-instruments-ltd&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>Service Center Spotlight</category>
      <pubDate>Thu, 20 Mar 2025 19:00:02 GMT</pubDate>
      <guid>https://info.teledyne-hi.com/blog/service-center-spotlight-chell-instruments-ltd</guid>
      <dc:date>2025-03-20T19:00:02Z</dc:date>
      <dc:creator>Wayne Lewey</dc:creator>
    </item>
    <item>
      <title>HVG-2020B Optional Display Features</title>
      <link>https://info.teledyne-hi.com/blog/hvg-2020b-optional-display-features</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://info.teledyne-hi.com/blog/hvg-2020b-optional-display-features" title="" class="hs-featured-image-link"&gt; &lt;img src="https://info.teledyne-hi.com/hubfs/HVG-2020B%20w%20hand-1.png" alt="HVG-2020B with finger touching screen" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Most people are aware that the HVG-2020B wide range vacuum gauge has an optional display, but not everyone realizes that it's much more than just a display. It's actually a color touchscreen display and is packed with features. Let's take a look.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/HVG-2020B%20View%20Toggle.png?width=264&amp;amp;height=118&amp;amp;name=HVG-2020B%20View%20Toggle.png" width="264" height="118" alt="HVG-2020B View Toggle" style="height: auto; max-width: 100%; width: 264px; float: right; margin-left: 10px; margin-right: 0px;"&gt;Most people are aware that the HVG-2020B wide range vacuum gauge has an optional display, but not everyone realizes that it's much more than just a display. It's actually a color touchscreen display and is packed with features. Let's take a look.&lt;/p&gt; 
&lt;p&gt;The HVG-2020B has 5 different display modes. Simply touch the icon on the lower left side to toggle through each one.&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2&gt;Available Views&lt;/h2&gt; 
&lt;p&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/HVG-2020B%20Display%20Options.png?width=1417&amp;amp;height=541&amp;amp;name=HVG-2020B%20Display%20Options.png" width="1417" height="541" alt="HVG-2020B Display Options" style="height: auto; max-width: 100%; width: 1417px;"&gt;&lt;/p&gt; 
&lt;ol&gt; 
 &lt;li&gt;&lt;strong&gt; Pressure View&lt;/strong&gt;: gives the pressure and units. Touching the pressure reading will toggle between decimal notation and scientific notation. Touching the units will cycle through available units (TORR, MBAR, KPA, PSIA, PSIG, ATM, BAR, PA).&lt;/li&gt; 
 &lt;li&gt;&lt;strong&gt; Pressure and Temperature View&lt;/strong&gt;: The screen adds a temperature indication. It is only meant to be a visual aid indicating ambient temperature (± 1.5 °C). Touching the temperature will toggle between °C and °F.&lt;/li&gt; 
 &lt;li&gt;&lt;strong&gt; Setpoint View&lt;/strong&gt;: The HVG-2020B has two setpoints. This view provides visual indicators of Hi and Lo setpoints. If the indicator is green the setpoint is active. The Hi setpoint is active when the pressure is above its setting and the Lo setpoint is active when the pressure is below its setting. The two settings may be different. Touching the Hi and Lo indicators will bring up a screen allowing the corresponding setpoint to be adjusted. Use the left/right arrows to select the digit and the up/down arrows to change the value of the digit.&lt;/li&gt; 
 &lt;li&gt;&lt;strong&gt; Bar Graph View&lt;/strong&gt;: A graphical indication of the current pressure on a log scale. Use it to quickly identify your desired pressure from across the room without having to read a number.&lt;/li&gt; 
 &lt;li&gt;&lt;strong&gt; Graph View&lt;/strong&gt;: A graphical indication of the pressure over time. Use it to identify the presence of a chamber leak and differentiate between a real leak and outgassing. Touching the screen anywhere will bring up a screen allowing the user to adjust the time (in seconds) per sample (displayed point). Use the left/right arrows to select the digit and the up/down arrows to change the value of the digit.&lt;/li&gt; 
&lt;/ol&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;h2&gt;Menu Features&lt;/h2&gt; 
&lt;h2&gt;&lt;img src="https://info.teledyne-hi.com/hs-fs/hubfs/Menu%20Features.png?width=184&amp;amp;height=212&amp;amp;name=Menu%20Features.png" width="184" height="212" alt="Menu Features" style="height: auto; max-width: 100%; width: 184px; float: right; margin-left: 10px; margin-right: 0px;"&gt;&lt;/h2&gt; 
&lt;p&gt;There are many more features that can be accessed simply by touching the Menu icon on the lower right side. Useful Menu features include:&lt;/p&gt; 
&lt;ul&gt; 
 &lt;li&gt;Screen Orientation&lt;/li&gt; 
 &lt;li&gt;Set Zero&lt;/li&gt; 
 &lt;li&gt;Device Info&lt;/li&gt; 
 &lt;li&gt;Analog Output&lt;/li&gt; 
 &lt;li&gt;Serial Port&lt;/li&gt; 
 &lt;li&gt;Restore Factory Defaults&lt;/li&gt; 
&lt;/ul&gt; 
&lt;p&gt;One of the most useful features is the ability to change the screen orientation. The HVG-2020B can be mounted in any orientation. This feature allows the user to rotate the screen to a position that is easy to read.&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&amp;nbsp;&lt;/p&gt; 
&lt;p&gt;&lt;strong&gt;The HVG-2020B is a wide range vacuum gauge that uses both pirani and piezoresistive technology to accurately measure 10&lt;sup&gt;-4&lt;/sup&gt; Torr to 1000 Torr. Learn more about the HVG-2020B at: &lt;/strong&gt;&lt;/p&gt; 
&lt;p&gt;&lt;a href="https://www.teledyne-hi.com/products-services/vacuum-measurement-and-control/hvg-2020b"&gt;https://www.teledyne-hi.com/products-services/vacuum-measurement-and-control/hvg-2020b&lt;/a&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=157992&amp;amp;k=14&amp;amp;r=https%3A%2F%2Finfo.teledyne-hi.com%2Fblog%2Fhvg-2020b-optional-display-features&amp;amp;bu=https%253A%252F%252Finfo.teledyne-hi.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>vacuum gauges</category>
      <pubDate>Tue, 18 Feb 2025 15:00:00 GMT</pubDate>
      <author>hastings_instruments@teledyne.com (The Teledyne Hastings Team)</author>
      <guid>https://info.teledyne-hi.com/blog/hvg-2020b-optional-display-features</guid>
      <dc:date>2025-02-18T15:00:00Z</dc:date>
    </item>
  </channel>
</rss>
